The efficient arc protection system

It is built to meet the growing demands in both LV and MV switchgear and controlgear applications ranging from basic stand-alone to more complex system solutions.

Application range of the AQ 100

The AQ 100 series is designed and tested according to the latest protection relay standards and is hence suitable for installations in any environment, such as utility, power plant, wind-power, off shore, marine, oil and gas, mining, steel or any other heavy industry application and as well commercial and institutional electrical systems. The AQ 100 modular design makes it an excellent candidate for both new and retrofit installations.

Advantages of the AQ 100

Speed

  • As fast as 2ms trip time
  • Connectivity to arc quenching system type
  • AQ 1000 and AQ 2000 for rapid arc extinguishing

Flexibility

  • Easy adaptation to any switchgear and trip scheme
  • Variety of arc sensors available
  • Long distance possible between units
  • Practically an unlimited number of units can be interconnected in one system

Reliability

  • Standard hard-wiring practice for communication between units
  • Superior isolation level for external disturbances – tested at the highest EMC classes
  • Selectable binary input threshold voltages
  • Full self-supervision of all system components and interconnections

Simplicity

  • AQ 100 Standard Arc Scheme (AQ-SAS*) approach for fast engineering and simple setting
  • Auto-configuration feature with one push-button operation
  • Installation downtime often limited to hours

Cost effectiveness

  • Careful component selection optimizes the AQ 100 cost structure
  • Use of standard cables for interconnection and sensor wiring
  • Quick install of sensors and wires
  • Cables can be cut to length on sit

Technical Data

Product variants

AQ-110F | 3 fiber loop sensors, connectivity to arc quenching system, 2 high speed outputs (2ms trip time), 4 trip relays (7ms trip time) *, 1 system failure relay, 1BO, 2BI,
Applicable sensors: AQ 06, AQ 07
AQ-110P | 12 point sensors, 1 fiber loop sensor (optional), connectivity to arc quenching system, 2 high speed outputs (2ms trip time), 4 trip relays (7ms trip time) *, 1 system failure relay, 1BO, 2BI,
Applicable sensors: AQ 01, AQ 01M, AQ 02, AQ 06 (optional), AQ 07 (optional)
AQ-102 | 3 fiber loop sensors, 4 trip relays (7ms trip time) *, 1 system failure relay, 1BO, 2BI, Insertable sensors: AQ 06, AQ 07
AQ-101 | 12 point sensors, 1 fiber loop sensor (optional), 4 trip relays (7ms trip time) *, 1 watchdog relay, 1BO, 2BI,
Applicable sensors: AQ 01, AQ 01M, AQ 02, AQ 06 (optional), AQ 07 (optional)
AQ-101D | as AQ-101 only for DIN rail
AQ-101S | 12 point sensors, 3 trip relays (7ms trip time) *, 1 system failure relay, 3BO, 6BI,
Applicable sensors: AQ 01, AQ 01M, AQ 02

Sensors

AQ 01 | a,b,c **Light sensor
AQ 01M | Portable sensor set
AQ 02 | light and pressure sensor
AQ 06 | plastic fibre sensor (5-50m length)
AQ 07 | fiber optic sensor (5-60m length)

*Optionally an electronic lock/trip relay available as normally closed contact
** a = 8,000 lux activation, b= 25,000 lux activation, c=50,000 lux activation